Who we are. Isoltech Green® is the European importer and developer of the panel-free facade insulation system (Pro-Tech® + Techdekor Green®). Pro-Tech® is a thermal corrector and hygrothermal facade regulator: it is not a substitute for a certified ETICS/EWI system. An European certification is in progress; we always send you the up-to-date documentary status.

Available documents

What we send you

Each document is described below. Tick the ones you need in the form: we will send them to you by email, in their current version.

ETA

ETA 20/0342 — European Technical Assessment

The base document for the system's CE marking. It describes the essential characteristics and declared values, including a declared thermal conductivity λD of 0.048 to 0.051 W/(m·K) and a water-vapour diffusion resistance factor µ of 5 to 20. A reference to cite in your technical files.

DoP

DoP — Declaration of Performance

The Declaration of Performance linked to the CE marking, which sets out the product's declared performances. Some values are being updated as part of the ongoing European certification; we provide the up-to-date version.

Data sheet

Pro-Tech® data sheet

Data sheet for the thermal-corrector render: composition, field of use, substrates, application and site conditions. Water absorption by capillarity of 0.17 kg/(m²·min^0.5), class W2. Pro-Tech® corrects thermal bridges and regulates the facade without replacing a certified ETICS/EWI system.

Data sheet

Techdekor Green® data sheet

Data sheet for the mineral finish applied over Pro-Tech®: appearance, shades, consumption and application. To be read together with the Pro-Tech® sheet to understand the complete system.

Fire

A2-s1,d0 fire classification

Reaction-to-fire classification according to EN 13501-1: the system is classified A2-s1,d0, i.e. a virtually non-combustible material with very low smoke emission and no flaming droplets or particles.

SDS

SDS — Safety Data Sheet

Possible hazards, handling precautions, storage and first aid for operatives. A document intended for site safety and regulatory compliance.

Specification

Application specification

A model specification for your tenders and prescriptions: substrate preparation, thicknesses, detailing, tolerances and acceptance. Designed for specifiers and engineering offices.

Reference

Reference project file — Católica Braga

A file documenting a reference project on the facades of the Universidade Católica de Braga. Provided subject to the university's authorisation.

Other reference values (test-based)

The system has undergone additional tests that we can document: solar reflectance index SRI 82 / solar reflectance 67% (LNE, ASTM E1980 method — this is solar performance, not thermal) and sound absorption coefficient αw 0.35 (TFI Aachen — this is sound absorption, not a sound-reduction index Rw). We only communicate values obtained from tests.

Why a request?

Reserved documents, fast response

These items are intended for professionals and their projects. A short request lets us send you the right version and support you during application. Response within 24–48 working hours.

Transparency. Some items (DoP, test reports) are being updated as part of the ongoing European certification. We always send you the up-to-date status at the time of your request.

Data protection. Your details are used only to respond to your documentation request. They are not shared with third parties.

Get the documentation

We send you the requested documents by email.

Request sent!

Thank you, we will send you the documents by email as soon as possible.
To move faster: +351 927 917 736

Call — +351 927 917 736