The thermal resistance of a homogeneous layer is calculated by dividing its thickness (converted to metres) by the thermal conductivity of the material: R = (e/1000)/λ, with e in millimetres and λ in W/(m·K). The result is expressed in m²·K/W. For example, 15 mm of a material with λ = 0.051 gives R = 0.015 / 0.051 ≈ 0.29 m²·K/W. The higher R is, the more the layer slows the heat flow.
Example value pre-filled: λ = 0.051 — the least favourable declared λD value from the Pro-Tech® ETA 20/0342. Your design office can use the material's real value. This field is free: enter the λ of any insulant.
For a homogeneous layer, the thermal resistance depends only on the thickness crossed and on the conductivity of the material:
R = e / λ (R in m²·K/W, e in m, λ in W/(m·K))The tool above first converts the thickness from millimetres to metres (dividing by 1000), then divides it by λ. Two useful behaviours to remember:
The resistance of a layer is a building block of the calculation: in a wall, the resistances of the successive layers add up, and the whole determines the U-value through U = 1/R_total. To compose a complete wall, use the U-value calculator.
The full definition of the quantity is detailed on the Thermal resistance page. The required U-values vary depending on local regulations.