Thermal conductivity (λ): definition, unit and measurement

What is thermal conductivity?

Thermal conductivity, written λ (lambda), measures a material's ability to conduct heat. It is expressed in watts per metre-kelvin, W/(m·K), and corresponds to the heat flow crossing one metre of thickness of the material for a one-kelvin temperature difference. The lower λ, the more insulating the material: still air and foams have a very low λ, metals a very high one.

Unit and physical meaning

The SI unit is W/(m·K) (sometimes written W/m·°C, equivalent for a temperature difference). It describes an intrinsic property of the material, independent of its thickness: λ characterises the matter, not the wall. It is the building block of all building thermal calculations.

Physically, λ results from conduction in the solid matter and, for porous insulants, from conduction and radiation within the trapped air cavities. This is why the best insulants exploit still air (or gas) immobilised in a fine structure: static air conducts heat very poorly.

Formula and link with resistance

Conductivity links the thickness of a layer to its thermal resistance:

R = e / λ  (R in m²·K/W, e in m, λ in W/(m·K))

So, for a target thermal resistance, the lower λ, the less thickness is needed. This is the central relationship between the material (λ) and the performance of the layer (R), which is itself aggregated into the wall's U-value.

Reference values (orders of magnitude)

These indicative values, drawn from building-physics literature, place the main families of materials:

MaterialIndicative λ — W/(m·K)Behaviour
Still air≈ 0.025Very insulating (if it does not circulate)
Insulants (wools, foams, wood fibre)≈ 0.030 – 0.045Dedicated insulants
Wood≈ 0.12 – 0.18Weakly conductive
Brick, plaster≈ 0.4 – 0.9Moderately conductive
Stone, concrete≈ 1.3 – 2.3Strongly conductive
Steel≈ 50Conductive (thermal bridge)
These figures are generic orders of magnitude. The value used in a project must come from the product's technical data sheet or a declared standardised value (λD), not from an estimate.

How is λ measured?

Conductivity is measured in the laboratory, on a test specimen, using standardised methods:

  • Guarded hot plate (ISO 8302 / EN 12667): the sample is placed between a hot plate and a cold plate; the flow needed to maintain the difference is measured.
  • Heat flow meter method (ISO 8301): a calibrated heat flow meter directly measures the flow crossing the sample.

The value depends on the mean test temperature, on density and above all on moisture: a damp material conducts heat far more. Data sheets therefore declare a λD value at standardised conditions.

Limits of interpretation

  • λ describes only conduction in steady state: it says nothing about inertia, time lag or radiation.
  • The real in-service value may differ from the lab value (moisture, settling, material bridges).
  • A low λ does not guarantee summer comfort, which depends on mass and time lag.