Yes, provided the wall's water-vapour behaviour is respected. Old stone or brick walls "breathe": they exchange moisture with the air. A Pro-Tech® thermo-active render is compatible with this vapour migration (µ ≈ 5–20), but on an old or sensitive wall a hygrothermal study (ISO 13788) is recommended before works, and compatibility with lime finishes is an asset. The substrate must be sound, dry and diagnosed.
Old walls — lime-bedded stone, solid brick, earth — work differently from an airtight modern wall. They are permeable to water vapour and naturally regulate part of the house's humidity. Applying a layer that is too closed on the inside can block this exchange, trap moisture in the wall and cause defects (detachment, saltpetre, degradation of renders).
The golden rule for old buildings is therefore to preserve this ability to let vapour pass through, while providing the thermal correction sought. This is the point that sets this job apart from that of a recent wall.
The Pro-Tech® thermo-active render has a water-vapour diffusion resistance factor µ between 5 and 20: it stays open to vapour migration and compatible with the wall's hygrothermal balance. It does not behave like a closed vapour barrier, which is consistent with the "breathing" logic of old buildings.
The finish of an old wall is readily done in lime, to stay within a vapour-open logic and respect the character of the building. The corrective render accepts compatible finishes — a finishing render, lime, or the Techdekor Green finish within the range, in a thin coat. Closed coverings (airtight films) that would hinder the sought-after vapour migration are avoided.
| Situation | Interior correction |
|---|---|
| Stone facade to preserve, protected area | Preferable: the outside cannot be altered |
| Room-by-room works, occupant present | Suited: localised intervention |
| Sound, dry wall, vapour behaviour verified | Possible after a hygrothermal study |
| Active rising damp, salts, saltpetre | Inadvisable until the cause is treated |
| Running wall or unstable substrate | To be excluded: treat the defect first |
Where active moisture is present, you treat the cause first before any correction (barrier against rising damp, remediation, ventilation). On old buildings more than anywhere else, a rigorous prior diagnosis is essential. The specificity of the substrate is why the dedicated page of the corrective-render guide exists: thermal correction of old buildings.
Pro-Tech® applied to the inside of an old wall is a thermal and comfort corrector: it raises the surface temperature and respects the wall's breathability, but it does not replace a full regulatory IWI system. Isoltech Green is the European importer/developer of the system (not its inventor) and European certification is underway. No R/U/λ value is attributed to a given element outside an identifiable report; the gains mentioned by customers (in the order of 40 to 60%) are customer feedback, not a guarantee.
This page is part of the interior thermal correction guide. See also the condensation and mouldy corners page and the old-house corrective render. Thicknesses and finishes depend on the building and on local regulations.