Condensation and mould in wall corners

Why does mould appear in wall corners?

Because corners and junctions are the coldest points of a wall: heat escapes there in two directions at once. When the surface drops below the dew point of the indoor air, water vapour condenses on it and the moisture feeds mould. Raising the surface temperature of these cold spots — by treating corners and cross walls continuously with a thermo-active render — and ventilating the room raises the fRsi factor and removes the condition for mould to appear.

The mechanism: dew point on a cold wall

The air in a home contains water vapour (cooking, showering, breathing, drying laundry). This air can only hold a limited amount of vapour, all the lower as it is cold. The dew point is the temperature at which the air, once cooled, becomes saturated: beyond it, vapour condenses into liquid water.

When a wall surface is colder than this dew point, the air in contact with it cools, saturates and deposits water on the wall. This persistent moisture on a cold surface creates the ideal breeding ground for mould — first as black patches in corners, behind furniture, at the base of walls and around windows.

Why corners and cross walls concentrate the cold

In a corner between two external walls, or at the junction with a cross wall or a floor, the inside surface is cooled from several sides at once, while the room's warm air circulates poorly there. These zones behave like thermal bridges: their surface temperature is lower than that of the plain wall, hence closer to the dew point. This is where condensation and mould start.

The role of the surface temperature factor fRsi

To make the risk objective, we use the surface temperature factor fRsi, defined by the ISO 13788 standard. It expresses, between 0 and 1, how far the inside surface stays "warm" relative to the gap between the indoor and outdoor air. The higher the fRsi, the further the surface is from the dew point and the lower the risk of condensation and mould.

Treating a cold spot therefore amounts to raising its fRsi. This is exactly the effect sought when you bring "surface warmth" back into the corners.

The treatment: continuous corners and cross walls + ventilation

Interior correction with a thermo-active render acts precisely on these cold spots. Pro-Tech® render is applied continuously, which allows the junctions to be treated without a break:

  • Return onto cross walls: the render returns over at least 1 metre along the cross wall, to warm the surface where the masonry runs through the wall.
  • Return onto the ceiling at the wall/slab junction, to treat the top corner.
  • Run-down at the wall base to the floor, with a possible return onto the floor over 1 m.
  • Corners treated continuously, with no joint or break in the material.

On the plain surface, the correction thickness is 10 mm (basic), 15 mm (enhanced) or 20 mm (cold or old wall). By raising the temperature of the cold spots, you increase their fRsi and move the surface away from the dew point.

Thermal correction acts on one of the factors (the surface temperature). It must always go hand in hand with suitable ventilation that removes the water vapour produced in the home: without air renewal, indoor humidity stays excessive. See the ventilation page.

Treat the cause of the moisture first

Condensation from a cold wall has nothing to do with rising damp or an infiltration: the diagnosis must distinguish these origins. Interior thermal correction is applied only on a sound and dry substrate (temperature > 5 °C, non-running substrate, ventilated room). Where there is rising damp, salts/saltpetre or uncontrolled active condensation, you treat the cause first (barrier, remediation, ventilation): applying a render on a damp wall masks the defect without solving it. Remember that Pro-Tech® is a thermal and comfort corrector, not a full regulatory IWI system.