The choice depends mostly on the facade and on the building's constraints. You correct from the outside whenever possible: the facade is accessible, its appearance can be altered and the works do not occupy the dwellings. You correct from the inside when the outside is forbidden or impossible: protected facade, co-ownership, party wall, appearance to preserve. With Pro-Tech® render applied from 10 to 20 mm, both approaches remain a thermal correction — not a substitute for a certified regulatory EWI or IWI system.
EWI (external wall insulation) treats the wall from the facade. IWI (internal wall insulation) treats it from the room. The Pro-Tech® system can be applied on either side, in a continuous coat with no framework, no added insulant and no through fixing. In both cases the chosen thickness starts at 10 mm (basic correction) and goes up to 20 mm (cold wall or old wall), depending on the substrate and the comfort objective.
| Criterion | Rather from the outside | Rather from the inside |
|---|---|---|
| Facade appearance | Alterable (ordinary facade) | To be preserved: protected building, street facade, co-ownership |
| Access / footprint | Accessible facade, scaffolding possible | Party wall, property boundary, narrow passage |
| Occupation of the premises | Works without entering the dwellings | Room by room, occupied dwelling possible |
| Usable floor area | Unchanged | Slightly reduced (low thickness: 10–20 mm) |
| Thermal bridges | Continuity across the whole facade | Returns to treat (cross walls, floors, reveals) |
| Water vapour | The wall dries towards the outside | Vapour management to study (old walls) |
Correcting from the outside does not reduce the usable floor area, treats the facade in a single continuity and does not force you to empty the rooms. It is the default approach when the facade is accessible and alterable. Where a conventional EWI runs into difficulty — overhang forbidden at a property boundary, reveals, slab edges, mouldings, historic centre — correction with a continuous render keeps precisely the advantage of low thickness. See the thermal correction guide and the thermal bridges guide.
You go through the inside when the outside is locked: a listed or protected facade whose appearance cannot change, a building in co-ownership where the facade is not yours alone, a party wall, or simply when you want to work room by room. Interior correction raises the surface temperature of the walls, removes the cold-wall effect and limits corner condensation. In return, it very slightly reduces the usable floor area and calls for treating the returns (cross walls, floors, ceilings, reveals) and managing water vapour.
By correcting from the inside, you change the wall's hygrothermal balance. Pro-Tech® stays open to diffusion (factor µ ≈ 5–20), which helps, but on an old wall a condensation study (ISO 13788) is recommended. A dry, sound, non-running substrate, a temperature above 5 °C and ventilation of the room are non-negotiable conditions: where there is rising damp, salts or active condensation, the cause is treated first.
Whether from the inside or the outside, Pro-Tech® is a thermal corrector: it acts on comfort, surface temperature and thermal bridges. It does not replace a full regulatory IWI or EWI system and does not, on its own, meet a regulatory thermal-transmittance requirement. Isoltech Green is the European importer and developer of the system; European certification is underway. For a quantified performance target, sizing is done project by project, with a design office, from the declared values — and, for a quantified regulatory requirement, a certified system remains the reference, depending on local regulations.
This page is part of the interior thermal correction guide. See also the thermal correction guide and the technical documentation.