Treating window reveals from the inside

Why treat window reveals after an interior correction?

Because the surround of a window — the reveal — is a cold spot where the thermal bridge concentrates: this is often where fogging and mould appear. By returning the Pro-Tech® thermo-active render into the reveals (return ≥ 5 mm), you extend the surface correction up to the window frame, raise the temperature of that surround and limit condensation, without moving or replacing the window.

The reveal: a thermal bridge around the window

The reveal is the strip of masonry bordering a window opening: the two vertical sides (jambs), the lintel at the top and the sill at the bottom. There, the wall is thinned around the frame and heat escapes easily: the reveal is a classic thermal bridge, whose inside surface is colder than the plain wall.

If you correct the surface of the wall from the inside without treating the reveal, you leave a cold band all around the window. This is precisely where fogging and, over time, mould patches settle. Treating the reveal is therefore the natural extension of the wall correction.

The return of the render into the reveal

The method consists of returning the Pro-Tech® render into the reveal, in continuity with the plain surface of the wall, up to the window frame. This return extends the thermo-active layer around the opening and cuts the flow that was bypassing the correction.

  • Return ≥ 5 mm into the reveal, applied in continuity with the corrected plain surface.
  • Treatment of the jambs, the lintel and, where possible, the sill, to wrap the whole surround.
  • A careful joint to the window frame, with no break in the material.
  • No work on the window: the window is neither removed nor moved.
The return into the reveals (≥ 5 mm) is a dimension specific to the surround of the opening; it is not to be confused with the correction thickness of the plain surface, which stays at a minimum of 10 mm (10 / 15 / 20 mm depending on the objective).

What treating the reveal brings

Before treatmentAfter the return into the reveal
Cold band around the windowWarmed surround, continuity of the correction
Fogging and condensation on the sides of the frameCondensation limited on the surround
Risk of mould at the wall/window jointCold spot softened, fRsi raised
Window to be keptWindow kept in place

By raising the surface temperature of the surround, you move the reveal away from the dew point and reduce the condition for condensation and mould to appear, in the logic described on the condensation and mouldy corners page.

Substrate and limits

As across the whole interior correction, the substrate of the reveal must be sound, dry and non-running (T > 5 °C, ventilated room). Sills and reveals subject to infiltration or rising damp must be treated at source before application. Pro-Tech® remains a thermal corrector: treating the reveals limits a surface thermal bridge but does not replace a regulatory insulation or the replacement of a failing window.

This page is part of the interior thermal correction guide. See the thermal bridges guide and the cold wall page.