Because perceived comfort does not depend on air temperature alone, but also on the temperature of the surfaces around us. Facing a cold wall, the body loses heat by radiation: we feel cold even though the thermostat reads 20 °C. This is the cold-wall effect. A thermo-active render such as Pro-Tech®, applied from the inside in 10 to 20 mm, raises the surface temperature of the wall and restores a sensation of comfort at equal air temperature.
Our sensation of warmth results from two main exchanges: convection with the ambient air and radiation with the surfaces around us. In front of a wall colder than the air, the body radiates more heat towards that surface than it receives. The result: a localised feeling of cold, a sensed "draught" where there is none, the urge to move away from the wall or to turn up the heating.
That is why a home can show a good air temperature and still feel uncomfortable if its walls are cold. The lever is not to add degrees to the air, but to warm up the surface of the walls.
Thermal comfort is better described by the operative temperature, which combines the air temperature and the mean temperature of the surfaces (radiant temperature). In practice it sits roughly halfway between the two. If the air is at 20 °C but the walls at 14 °C, the operative temperature drops well below 20 °C: we feel cold.
Conversely, by raising the surface temperature of the walls, you increase the operative temperature without touching the thermostat. This is the very principle of interior thermal correction: acting on radiant comfort rather than on the air alone.
| Situation | Air | Wall surface | Feeling |
|---|---|---|---|
| Uncorrected cold wall | 20 °C | Low | Discomfort, sense of cold near the wall |
| After surface correction | 20 °C | Higher | Comfort restored at the same air temperature |
The plain body of a wall — stone, brick, concrete — has an inside surface temperature that is all the lower as the wall is poorly insulating and exposed to the cold. By applying a continuous thermo-active render from the inside, you interpose between the room and the cold masonry a layer that slows the heat flow: the visible face of the render stays closer to the air temperature.
Pro-Tech® is applied with no framework, no added insulant and no mechanical fixings, in a thickness of 10 mm (basic correction), 15 mm (enhanced comfort) or 20 mm (cold wall or old wall). The continuous application lets it wrap the corners and junctions, where the cold-wall effect is most pronounced.
This correction targets the feeling: softening the cold wall, evening out the surfaces, reducing the urge to overheat. It does not replace a full regulatory IWI system and must not be presented as one. Its performance depends heavily on the substrate; a prior diagnosis is essential.
A cold wall is sometimes also a damp wall, and moisture worsens the sensation of cold (a damp material conducts heat better). Before any correction, the substrate must be sound, dry and non-running, at a temperature above 5 °C and with ventilation of the room. Where there is rising damp, salts or active condensation, the cause is treated first. This point ties in with the page on condensation and mouldy corners.
This page is part of the interior thermal correction guide. See also the thermal bridges guide and the technical documentation.