A damp wall insulates poorly: water increases thermal conductivity and makes the wall's resistance collapse. Insulating without treating the cause traps moisture, promotes mould and salt efflorescence and damages the fabric. The source must first be identified — rising damp, condensation or infiltration — because each cause calls for a different treatment. Diagnosis always precedes thermal correction.
The thermal performance of a wall assumes it is dry. A damp material sees its thermal conductivity (λ) rise sharply: water, a far better conductor than the air trapped in the pores, short-circuits the insulating power. A water-logged wall can lose a significant part of its thermal resistance. Moreover, moisture lowers the internal surface temperature and promotes condensation, and therefore mould. Treating the thermal behaviour without treating the water amounts to hiding a symptom.
| Origin | Typical signs | Location |
|---|---|---|
| Rising damp | Tide mark at the base of the wall, salt efflorescence, blistering render | Lower part of walls, up to 1–1.5 m |
| Condensation | Misting, black mould in corners and behind furniture | Cold spots, corners, poorly ventilated damp rooms |
| Infiltration | Localised stains, appearing after rain | Roof, joints, sills, cracks, buried services |
Common in old buildings without a capillary break: ground water rises by capillarity through the pores of the masonry, carrying salts that crystallise at the surface (efflorescence). It is recognised by a horizontal tide mark at the base of the wall.
It occurs when vapour-laden indoor air meets a surface colder than its dew point. It is linked to cold spots (thermal bridges, cold wall) and to insufficient ventilation. It is a problem of surface temperature and air renewal.
Rain or run-off water entering through a defect: roofing, flashing, a degraded joint, a crack, a window sill, or splash-back at the base of the wall. The stains are localised and often correlated with rainy spells.
The logical sequence avoids costly mistakes:
Pros: durable result, a wall that recovers its insulating power, no recurrence. Cons: drying time, several trades sometimes needed.
Major cons: trapped moisture, mould behind the insulant, salt efflorescence, decay of the fabric and loss of performance. No real advantage; it is the main mistake in renovating old buildings.
Once the cause of moisture has been treated and the wall is drying out, the thermal correction must stay vapour-open so as not to re-block the wall. A panel-free mineral system such as the Pro-Tech® thermo-active render (distributed by Isoltech Green across Europe) offers the qualitative advantage of a continuous breathable envelope, without through fixings. It comes in after remediation, never in its place: it does not treat rising damp or infiltration, which call for specific works. It is an alternative to EWI, especially where EWI cannot be installed.
For transparency, we do not publish any λ, R or U figure attributed to Pro-Tech® outside an identifiable report; the savings reported by our customers (in the order of 40 to 60%) are customer feedback obtained on sound walls. Diagnosis and treatment of water remain the absolute precondition of any thermal correction.
This article complements the thermal correction of buildings guide and the old-building hub. See also Ventilation.