An older period house (typically built before the mid-20th century) must be treated as a "breathing" whole: thick walls in stone, brick or timber frame, bedded in lime mortar and without a capillary break. It is insulated by keeping this vapour permeability, by treating moisture first, then correcting the thermal behaviour — preferably from the outside to keep the thermal mass, except where the facade must be preserved.
Older building stock varies greatly from region to region, but shares common traits. The walls are thick (often 40 to 70 cm), solid and bedded in lime or earth mortar, without the capillary breaks and waterproof barriers of modern work. You mainly find:
These walls were not designed to be watertight: they manage water by absorbing and releasing it. Any intervention must preserve this balance.
Traditional materials conduct heat (high λ for stone, moderate for brick and earth): the winter thermal resistance of a bare old wall stays low and the inner face cold. On the other hand, the high mass delivers remarkable thermal mass and time lag: the old house often stays cool in summer, an asset not to be destroyed.
Lime renders, open mortars, earth floors: the whole continuously exchanges water vapour with the air and the ground. Introducing a sealed material in the wrong place (cement, closed insulant, plastic coating) upsets this system and causes damp, salt efflorescence and decay. The golden rule for old fabric: do not block vapour migration.
| Element | Common solution | Old-building note |
|---|---|---|
| Walls | Breathable correction/EWI or breathable IWI | External if the facade can be altered; otherwise internal with a vapour study |
| Roof / loft | Loft insulation (often the economic priority) | Biggest heat-loss area, fast payback |
| Ground floors | Insulation under the floor or at the soffit | Keep the crawl-space ventilated |
| Joinery | Repair or replacement, suitable double glazing | Don't over-seal without ventilating |
| Ventilation | Mechanical ventilation suited to the fabric | Essential after improving air-tightness |
On the walls, the trade-off is the same as for stone and brick: breathable external correction when the facade can be altered (thermal mass preserved, thermal bridges treated), breathable internal correction where the appearance must be kept. In all cases, ventilation is the essential corollary of any improvement to air-tightness.
Pros: thermal mass and summer comfort preserved, thermal bridges treated, facade renewed, no loss of space. Cons: changes the appearance (incompatible with some protected facades), requires an accessible facade and a sound substrate.
Pros: facade preserved, room-by-room work, sometimes more affordable. Cons: loss of mass and space, thermal bridges difficult, risk of condensation in the mass if vapour is badly managed.
On the walls of an older house, a panel-free correction system such as the Pro-Tech® thermo-active render (distributed by Isoltech Green across Europe) offers a continuous mineral envelope in low thickness, consistent with the breathable logic of old fabric: it treats junctions without interruption, keeps the thermal mass on the heated side and renews the facade in one operation. The value is qualitative; the final performance depends on the substrate, the thickness applied and the whole project (roof, joinery, ventilation). It is an alternative to EWI, especially where EWI cannot be installed.
In technical honesty, we do not publish any λ, R or U figure attributed to Pro-Tech® outside an identifiable report. The savings reported by our customers (in the order of 40 to 60%) are customer feedback. Treating moisture and ventilation stay the priority. Where a quantified regulatory U requirement is targeted on a regular facade, a certified EWI system remains the reference.
This article complements the thermal correction of buildings guide and the old-building hub. See also Ventilation and the thermo-active render guide.