How to improve the thermal comfort of old walls — solid, vapour-open and moisture-sensitive — without harming them. A complete, sourced and transparent guide, with six detailed articles by wall and building type.
Old buildings are corrected by respecting two principles: keep the wall breathing (vapour-open materials, no sealed barrier) and deal with moisture before adding any thermal layer. An external treatment in a continuous envelope is usually preferred, to keep the thermal mass and remove thermal bridges — except where the facade must be preserved. Each wall type — stone, brick, earth — calls for an adapted response.
Buildings from the pre-modern era were not designed like today's construction. Their walls are thick, solid and bedded in lime or earth mortar, without the capillary breaks and waterproof barriers of modern work. They have always worked by exchanging moisture with the air and the ground: they absorb water and release it again. Trying to make them watertight, like a new wall, upsets this behaviour and causes damp, salt efflorescence and decay.
Two features dominate: high thermal mass, valuable for summer comfort, and a modest winter thermal resistance, the source of the cold-wall effect. The whole strategy consists of raising winter performance without destroying the mass or blocking breathability.
Physically, an old wall combines several quantities that have dedicated articles in our thermal-science cluster:
Thermal performance assumes a dry wall: moisture increases conductivity and makes resistance collapse. Managing water is therefore the precondition of any correction.
The choice is made after a survey, according to the nature of the wall, its moisture state, the value of the facade and the objective sought.
| Criterion | Internal correction (IWI) | External correction (EWI) |
|---|---|---|
| Useful thermal mass | Reduced (mass on the cold side) | Preserved (mass on the heated side) |
| Thermal bridges | Hard to treat | Treated continuously |
| Facade / heritage | Appearance preserved | Altered (to be checked if protected) |
| Living space | Reduced | Unchanged |
As a general rule, vapour-open external correction is preferable as soon as the facade can be altered. Internal correction is required on protected facades or those to be kept, with a careful study of vapour migration (Glaser method, ISO 13788 standard).
Every situation has a full article: wall make-up, hygrothermal behaviour, constraints, possible solutions, pros and cons, selection criteria.
Isoltech Green distributes across Europe a panel-free facade correction system: the Pro-Tech® thermo-active render, applied as a continuous envelope without adhesive or fixings, paired with the Techdekor Green finish. On old buildings its value is qualitative: a continuous, breathable mineral envelope, in low thickness, that follows irregular substrates, treats junctions without interruption and keeps the wall's thermal mass on the heated side. It is an alternative to external wall insulation (EWI), especially where EWI cannot be installed.
For transparency, we do not publish any λ, R or U figure attributed to Pro-Tech® outside an identifiable report; the savings reported by our customers (in the order of 40 to 60%) are customer feedback, distinct from a laboratory measurement. Treating moisture remains the precondition, and where a quantified regulatory U requirement is targeted on a regular facade with no thickness constraint, a certified EWI system remains the reference.
Stone, brick, heritage: the right system is decided after analysing the wall and its moisture state. Let's talk about your project.
For the fundamentals (quantities, formulas, standards), see the general guide and the thermal-science cluster: