An old brick wall is insulated with its vapour permeability in mind: fired clay absorbs and releases moisture, so this breathing must be preserved with vapour-open materials, rather than sealed barriers that would make water stagnate. The wall is corrected preferably from the outside to keep the thermal mass and treat thermal bridges, after checking the moisture state and the adhesion of the existing renders.
Fired-clay brick comes in several families with distinct behaviour:
Bricks are bedded in lime mortar (old building) or cement (more recent work). Lime mortar, being vapour-open, contributes to moisture regulation. An old solid-brick wall 30 to 50 cm thick is therefore massive, porous and vapour-permeable.
Fired clay is a porous, hygroscopic material: it absorbs moisture from the air when it is high, and releases it when the air dries out. This moisture-buffering capacity regulates the indoor climate but makes the wall sensitive to water: saturated with moisture, it loses insulating power sharply, because its conductivity (λ) rises with water content.
Solid, dense brick offers appreciable thermal mass and a good time lag, favourable to summer comfort. Hollow brick, being lighter, offers less. In winter, like stone, a bare brick wall loses heat and presents a cold inner face, a source of discomfort and of condensation in corners.
A brick saturated with water can suffer frost damage (surface spalling) and see soluble salts migrate (efflorescence). Blocking evaporation on the wrong side worsens these phenomena: vapour management stays central.
| Approach | Principle | Facade appearance | Vapour management |
|---|---|---|---|
| Breathable correction / EWI | Corrective render or vapour-open EWI as a continuous envelope | Altered (covers the brick) | Favourable if the system is breathable |
| Internal insulation (IWI) | Insulation build-up + lining, controlled vapour management | Preserved (exposed brick kept) | Tricky: Glaser study needed |
| Lime insulating render | Breathable correction in low thickness | Altered | Very good |
The choice depends first on the value of the facade. On rendered brick or brick with no visible heritage interest, vapour-open external correction keeps the thermal mass and treats thermal bridges. On exposed brick to be preserved, a breathable internal correction is chosen, while monitoring vapour migration (Glaser method, ISO 13788) to avoid condensation in the mass.
Pros: thermal mass preserved, thermal bridges treated continuously, facade renewed, low thickness possible. Cons: hides exposed brick, requires an accessible facade and a sound substrate, resistance per centimetre lower than a dedicated insulant.
Pros: keeps the exposed-brick facade, can be done room by room. Cons: loss of space, thermal mass neutralised, thermal bridges difficult, risk of interstitial condensation if vapour is badly managed.
On a rendered brick wall or one with no heritage constraint on the facade, a panel-free correction system such as the Pro-Tech® thermo-active render (distributed by Isoltech Green across Europe) provides a continuous mineral envelope in low thickness, which treats floor and lintel thermal bridges without interruption and keeps the wall's thermal mass on the heated side. The value here is qualitative: continuity, no through fixings, compatibility with a fired-clay substrate. It is an alternative to EWI, especially where EWI cannot be installed.
For transparency, we do not publish any λ, R or U figure attributed to Pro-Tech® outside an identifiable report. The gains reported by our customers (in the order of 40 to 60%) are customer feedback, distinct from a laboratory measurement. Vapour compatibility and substrate adhesion are checked project by project. On a flat facade with no thickness constraint and a target of very low U, a certified EWI system remains the reference.
This article complements the thermal correction of buildings guide and the old-building hub. See also the panel-free facade insulation guide.