Old-building guide · fired-clay masonry

Insulating an old brick wall while respecting its breathing

How do you insulate an old brick wall?

An old brick wall is insulated with its vapour permeability in mind: fired clay absorbs and releases moisture, so this breathing must be preserved with vapour-open materials, rather than sealed barriers that would make water stagnate. The wall is corrected preferably from the outside to keep the thermal mass and treat thermal bridges, after checking the moisture state and the adhesion of the existing renders.

What is an old brick wall made of?

Fired-clay brick comes in several families with distinct behaviour:

  • Traditional solid brick: dense, massive, very common in 19th and early-20th-century urban building. Strong thermal mass, but high λ.
  • Hollow brick and perforated brick: lighten the wall and introduce air pockets that slightly improve thermal resistance, but stay far below a dedicated insulant.
  • Regional bricks (southern "forain" brick, flemish bricks and others) have varying porosities and dimensions.

Bricks are bedded in lime mortar (old building) or cement (more recent work). Lime mortar, being vapour-open, contributes to moisture regulation. An old solid-brick wall 30 to 50 cm thick is therefore massive, porous and vapour-permeable.

Hygrothermal behaviour of fired clay

A marked hygroscopic capacity

Fired clay is a porous, hygroscopic material: it absorbs moisture from the air when it is high, and releases it when the air dries out. This moisture-buffering capacity regulates the indoor climate but makes the wall sensitive to water: saturated with moisture, it loses insulating power sharply, because its conductivity (λ) rises with water content.

Thermal mass and summer comfort

Solid, dense brick offers appreciable thermal mass and a good time lag, favourable to summer comfort. Hollow brick, being lighter, offers less. In winter, like stone, a bare brick wall loses heat and presents a cold inner face, a source of discomfort and of condensation in corners.

Sensitivity to frost and salts

A brick saturated with water can suffer frost damage (surface spalling) and see soluble salts migrate (efflorescence). Blocking evaporation on the wrong side worsens these phenomena: vapour management stays central.

The constraints specific to brick

  • Preserve breathability. A sealed external coating can trap water in the brick and promote frost damage and efflorescence.
  • Character facades. Many exposed-brick walls (polychrome bricks, decorative bonds) have architectural value to preserve, which steers towards internal correction.
  • Adhesion of renders. On rendered brick, the condition and adhesion of the existing render govern whether external correction can be applied.
  • Structural thermal bridges. Floors, lintels and ring beams create cold lines that a continuous external envelope treats effectively.
As with any old masonry, diagnose and treat rising damp and infiltration before adding a thermal layer. A damp brick wall insulates poorly and decays in frost.

Possible solutions

ApproachPrincipleFacade appearanceVapour management
Breathable correction / EWICorrective render or vapour-open EWI as a continuous envelopeAltered (covers the brick)Favourable if the system is breathable
Internal insulation (IWI)Insulation build-up + lining, controlled vapour managementPreserved (exposed brick kept)Tricky: Glaser study needed
Lime insulating renderBreathable correction in low thicknessAlteredVery good

The choice depends first on the value of the facade. On rendered brick or brick with no visible heritage interest, vapour-open external correction keeps the thermal mass and treats thermal bridges. On exposed brick to be preserved, a breathable internal correction is chosen, while monitoring vapour migration (Glaser method, ISO 13788) to avoid condensation in the mass.

Pros and cons

External correction

Pros: thermal mass preserved, thermal bridges treated continuously, facade renewed, low thickness possible. Cons: hides exposed brick, requires an accessible facade and a sound substrate, resistance per centimetre lower than a dedicated insulant.

Internal insulation

Pros: keeps the exposed-brick facade, can be done room by room. Cons: loss of space, thermal mass neutralised, thermal bridges difficult, risk of interstitial condensation if vapour is badly managed.

Selection criteria

  • Exposed brick to be kept? If so, internal is required; otherwise, external is often preferable.
  • Moisture state and frost: a wall prone to damp and frost must be dried out and stay breathable.
  • Performance target: comfort and cold wall → correction; low regulatory U → thick dedicated insulant.
  • Available thickness on the facade (sills, overhangs, building line).

Where can a thermo-active render such as Pro-Tech® fit?

On a rendered brick wall or one with no heritage constraint on the facade, a panel-free correction system such as the Pro-Tech® thermo-active render (distributed by Isoltech Green across Europe) provides a continuous mineral envelope in low thickness, which treats floor and lintel thermal bridges without interruption and keeps the wall's thermal mass on the heated side. The value here is qualitative: continuity, no through fixings, compatibility with a fired-clay substrate. It is an alternative to EWI, especially where EWI cannot be installed.

For transparency, we do not publish any λ, R or U figure attributed to Pro-Tech® outside an identifiable report. The gains reported by our customers (in the order of 40 to 60%) are customer feedback, distinct from a laboratory measurement. Vapour compatibility and substrate adhesion are checked project by project. On a flat facade with no thickness constraint and a target of very low U, a certified EWI system remains the reference.

Go further

This article complements the thermal correction of buildings guide and the old-building hub. See also the panel-free facade insulation guide.

Call — +351 927 917 736