The inside surface temperature, written Tsi, is the temperature of a wall's inside face (wall, ceiling, glazing), expressed in °C. It depends on the wall's U-value and on the ambient conditions: the more insulating the wall, the closer its surface stays to the indoor air temperature. A surface that is too cold creates a cold-wall sensation and, if it drops below the dew point, a risk of condensation and mould.
The inside surface temperature is not a fixed property of the wall: it results from the balance between the heat crossing the wall and the exchanges at its surface. It depends on:
The more insulating the wall (low U), the closer the inside surface stays to the air temperature. A highly lossy wall, on the contrary, lets its surface cool: it is the "cold wall" felt when approaching it, which degrades the perceived operative temperature.
The dew point is the temperature at which the air, once cooled, reaches saturation (100% relative humidity) and begins to condense its water vapour. If a wall's surface temperature drops below the dew point of the ambient air, water deposits on that surface: this is surface condensation.
This phenomenon is the classic starting point for mould, which can develop even before visible condensation, as soon as the relative humidity at the surface stays durably high. The most exposed zones are corners, window reveals and thermal bridges, colder than the rest of the wall.
To judge the risk of condensation and mould at a cold spot, the surface temperature factor fRsi is used, defined by the ISO 13788 standard:
fRsi = (Tsi − Te) / (Ti − Te)where Tsi is the inside surface temperature, Ti the indoor air temperature and Te the outdoor air temperature. The result is a dimensionless number between 0 and 1.
The criterion is to check that the calculated fRsi stays above a required minimum value, itself deduced from the ambient conditions and climate to prevent the surface from reaching critical humidity. Singular points (corners, junctions) are calculated in a two-dimensional regime under ISO 10211.
Consider a room at Ti = 20 °C and an outside at Te = 0 °C. On a well-insulated main part of the wall, the surface may stay around 18–19 °C: the fRsi is high, well above the usual thresholds. In a poorly treated corner, the same wall may see its surface fall to a few degrees above the outside: the fRsi drops, and this is precisely where mould appears first.
Two families of approach coexist, which must be clearly distinguished:
| Approach | Tool / method | Use |
|---|---|---|
| On-site measurement | Contact surface thermometer | Point reading of a surface |
| On-site measurement | Thermal camera — infrared thermography (EN 13187) | Mapping of cold spots and thermal bridges |
| Condensation diagnosis | Surface probe + ambient hygrometer | Compare Tsi with the calculated dew point |
| Calculation / simulation | Thermal model (ISO 13788, ISO 10211) | Predict fRsi and risk before works |
Infrared thermography, framed by EN 13187 for the detection of thermal irregularities in the envelope, visualises the cold zones directly. Pairing a surface probe with hygrometry lets you compare the surface temperature with the current dew point.
This page complements the Thermal correction of facades guide.