Page · thermal quantity

Thermal time lag: delaying the entry of summer heat

What is the thermal time lag?

The thermal time lag is the time, expressed in hours, that an outdoor heat peak takes to cross a wall and reach its inside face. A good time lag, in the order of 8 to 12 hours, shifts the afternoon heat towards the night, when it is cooler. It comes with a decrement: the temperature amplitude is reduced as it crosses the wall. It is a key indicator of summer comfort.

Time lag and decrement

Two effects go hand in hand when a heat wave crosses a wall:

  • The time lag (or time shift): the inside peak arrives several hours after the outside peak.
  • The decrement: the amplitude of the inside peak is lower than that of the outside peak. It is quantified by a decrement factor (the ratio of amplitudes), always below 1.

A wall that performs well in summer combines a long time lag and strong decrement: the heat arrives late and weakened. This behaviour belongs to the dynamic state and extends the notion of thermal inertia.

Link with thermal diffusivity

The time lag depends on the speed at which heat diffuses through the material, measured by thermal diffusivity a:

a = λ / (ρ · c)  (a in m²/s, λ in W/(m·K), ρ in kg/m³, c in J/(kg·K))

A low diffusivity (a material that transmits heat slowly) combined with a large thickness gives a long time lag. In other words: the thicker, denser and higher in specific heat the wall, the longer the peak takes to cross it. The time lag generally increases with thickness and decreases as diffusivity rises.

Thickness, density and layer order

Three levers act on a wall's time lag. First, thickness: for a given material, a thicker layer delays the peak more. Then density and specific heat, which reduce diffusivity and slow the propagation of heat: a heavy material with high storage capacity shifts the peak better than a light one, even an insulating one. Finally, the order of the layers matters: a mass placed on the inside does not play the same role as a mass on the outside. The time lag is therefore always calculated on the complete composition of the wall, layer by layer, and never on a single isolated material.

Orders of magnitude

Qualitative markers to place wall families (the exact values depend on the real thickness and composition):

Type of wallIndicative time lagSummer behaviour
Light, poorly insulated wall≈ 2 – 4 hThe peak arrives fast: afternoon overheating
Ordinary insulated wall≈ 5 – 8 hPartial shift towards the evening
Heavy or thick wall≈ 8 – 12 hPeak shifted to the night: favourable
Massive old wall (thick stone)> 10 hHeat strongly delayed and damped
Generic orders of magnitude. A given wall's time lag is calculated from its real composition (thicknesses, materials, layer order) and cannot be deduced from a single isolated figure.

Role in summer comfort

A time lag of about 8 to 12 hours shifts the outdoor heat peak from the middle of the afternoon to the middle of the night. At that moment the outdoor air is cooler, and night-time ventilation allows the heat released by the wall to be removed. It is a major lever for the summer comfort of roofs and walls exposed to the south and west, particularly useful where the day is very hot and the night milder.

Time lag and decrement complement one another: shifting the peak is not enough if it stays intense. A wall that shifts the heat by ten hours but barely dampens it can still overheat the interior in the evening. Conversely, strong decrement combined with a medium time lag clearly softens the felt amplitude. It is the combination of the two, on a wall properly insulated in other respects, that provides a stable environment in hot periods. The roof, the surface most exposed to summer solar radiation, is where this dynamic behaviour matters most.

How is the time lag calculated?

The time lag and decrement are part of a wall's dynamic thermal characteristics, defined and calculated under the EN ISO 13786 standard, in periodic regime (a sinusoidal stress with a 24 h period). The calculation, usually built into dynamic thermal simulation software, uses the conductivity, density, specific heat and thickness of each layer.

The real time lag can also be observed through in-situ monitoring of the outside and inside surface temperatures. The calculation value (standardised), the simulation result and the site measurement are then distinguished.

Limits of interpretation

  • The time lag is a calculation value under a theoretical sinusoidal regime; the real behaviour depends on the weather, orientation and actual sunshine.
  • It is mostly relevant in summer, for roofs and exposed walls; it brings nothing in winter.
  • It does not replace winter insulation: a wall can have a good time lag and an insufficient thermal resistance R.
  • Without a possibility of night-time discharge (ventilation, night coolness), the benefit of the time lag is reduced.

Go further

This page complements the Thermal correction of facades guide.