Guide · critical junction

Ground floor

Why does the ground floor create a thermal bridge?

A building's ground floor rests on its perimeter wall; at this junction, the floor insulation and the wall insulation struggle to meet, and the masonry provides a conductive path between the inside and the surrounding environment (ground, crawl space or basement). This thermal bridge at the base of the wall lowers the temperature at floor level, creates a sensation of a cold floor and a risk of condensation along the skirting boards. It is quantified by a linear coefficient ψ (W/m·K) and depends strongly on the position of the insulation and the type of substructure.

Three ground-floor situations

The physics of the bridge depends on what lies beneath the floor:

  • Slab on ground: the slab is cast on the ground. The exchanges occur mainly around the perimeter; the ground itself tempers the centre of the slab, but the base of the wall remains a cold point.
  • Floor over crawl space: a ventilated space separates the floor from the ground, which exposes the underside to a temperature close to the outside and accentuates the bridge at the perimeter.
  • Floor over unheated basement: the floor separates the heated volume from a cold space; the junction with the load-bearing wall forms the bridge.

In all three cases, the sensitive point is the ground floor / perimeter wall junction, where floor insulation, wall and substructure meet.

How is it quantified?

The bridge is characterised by a linear coefficient ψ applied to the perimeter of the ground floor.

Heat loss at the base of the wall:  Hψ = ψ · Pfloor  (P = perimeter of the ground floor in m)

The value is determined by the default values of EN ISO 14683 or by a detailed ISO 10211 calculation. For slabs on ground, calculating the heat loss through the ground also involves the standard ISO 13370, which deals with heat transfer to the ground and separates the surface part from the perimeter part.

Junction configurationIndicative ψ (W/m·K)Cold floor felt
Floor and wall insulation in continuity (perimeter insulation)≈ 0.10 – 0.30Limited
Floor insulation only, base of wall untreated≈ 0.30 – 0.60Pronounced
No insulation at the base of the wall (crawl space)≈ 0.50 – 0.90Strong
Generic orders of magnitude drawn from published building physics. The real ψ depends on the substructure, the position of the insulation and the type of floor; it is calculated to EN ISO 14683, ISO 10211 and, for slab on ground, ISO 13370. These benchmarks do not replace a project calculation.

Consequences

The ground-floor bridge results in a cold floor around the perimeter and in a low internal surface temperature along the walls, at floor level. Condensation is frequently observed behind low furniture and along skirting boards, with a risk of mould. It is also a source of discomfort from cold feet, even when the ambient air is at a good temperature.

How is this thermal bridge treated?

The principle is to re-establish the continuity of the insulation between the floor and the wall. Depending on the access and the type of substructure:

  • Perimeter insulation: continue the substructure insulation into the lower part of the wall, so that it meets the floor insulation.
  • Underside insulation (accessible crawl space or basement): insulate the underside of the floor, carefully treating the junction with the wall.
  • Continuity from the outside: bring the facade insulation down to the base of the wall, a continuously applied render limiting residual junctions.

As with any critical junction, this bridge is not "removed": it is strongly reduced through the continuity of the application, then the result is verified by calculation or by thermography. The wall-floor junction describes the general geometry of this junction.

Limits of interpretation

  • Bringing insulation down to the base of the wall may run up against level constraints (thresholds, accessibility) and rising damp.
  • The default values of EN ISO 14683 are conservative; the ISO 10211 calculation (and ISO 13370 on slab on ground) is more reliable.
  • The thermal bridge must be distinguished from rising damp: a cold base of wall can also reveal rising moisture, which calls for a different treatment.
  • Depending on the building, a conventional EWI or IWI with treatment of the base of the wall may remain the best-suited solution.