Guide · critical junction

Party wall

Why does a party wall create a thermal bridge?

A party wall is an internal load-bearing wall that runs through the building and butts against the facade. When insulation is installed on the inside, the party wall interrupts it at every junction with the external wall: the party-wall masonry directly links the heated indoor air to the cold facade, like a conductive rib. The result is a vertical junction thermal bridge, a cold point at an internal wall corner, and a risk of condensation and mould in that corner. It is quantified by a linear coefficient ψ (W/m·K). Treated from the outside, this bridge largely disappears.

The bridge that distinguishes IWI from EWI

The party wall is the classic example of the thermal bridge that internal insulation cannot easily treat. With IWI, the insulation stops where the party wall meets the facade, leaving the party-wall masonry in thermal contact with the outside. With EWI, on the contrary, the insulation is installed on the outside: it passes in front of the facade without being interrupted by the internal party walls, which then remain on the warm side of the insulation. This is one of the major physical arguments in favour of external insulation.

How is it quantified?

The bridge is characterised by a linear coefficient ψ applied to the height of the party-wall / facade junction, at each storey where the party wall meets the external wall.

Heat loss of the party wall:  Hψ = ψ · Ljunction  (L = combined height of the party-wall / facade junctions)

The value is determined by the default values of EN ISO 14683 or by a detailed ISO 10211 calculation. The contrast between IWI and EWI is particularly clear here.

ConfigurationIndicative ψ (W/m·K)Cold point at the corner
External insulation (party wall on the warm side)≈ 0.00 – 0.05Negligible
Internal insulation with insulation return on the party wall≈ 0.10 – 0.30Reduced
Internal insulation without return≈ 0.30 – 0.60Pronounced
Generic orders of magnitude drawn from published building physics. The real ψ depends on the thickness of the party wall, the masonry and the insulation solution; it is calculated to EN ISO 14683 or ISO 10211. These benchmarks do not replace a project calculation.

Consequences

The party wall lowers the internal surface temperature in the corner formed by the party wall and the facade wall. This corner, where air circulates less and where two cold surfaces meet, is a favoured site of surface condensation and then mould — a frequent defect in older dwellings insulated from the inside. The bridge also contributes to the heat loss of the envelope, all the more so where party walls are numerous.

How is a party wall's thermal bridge treated?

Two approaches, very unequal:

  • From the outside: EWI solves the party-wall bridge almost inherently, since the continuous facade insulation leaves the party wall on the warm side. A continuously applied render reinforces this advantage by avoiding joints.
  • From the inside: where only IWI is possible, the bridge is limited by an insulation return onto the faces of the party wall, over a sufficient depth on the inside. This return reduces the bridge without eliminating it; a residual bridge remains.

So this bridge is not systematically "removed": from the outside it is largely eliminated, from the inside it is reduced. In both cases, the result is verified by calculation or by thermography, targeting the internal corner.

Limits of interpretation

  • The party wall illustrates why EWI is often preferable; but EWI is not always feasible (heritage, shared boundaries, planning).
  • The insulation return in IWI encroaches on the usable floor area and remains limited in depth.
  • The default values of EN ISO 14683 are conservative; an ISO 10211 calculation is more reliable.
  • Depending on the building, a conventional IWI with carefully executed returns may remain the best-suited solution, accepting documented residual bridges.

This guide complements the Thermal correction of buildings dossier and the Thermal bridges cluster. Isoltech Green is a European distributor; the choice of a solution falls to a project study.