IWI & residual thermal bridges

Why does IWI leave residual thermal bridges?

Internal wall insulation (IWI) places the insulation on the internal face of the walls. The structure — slabs, party walls, floors — then stays on the cold side, and every element that meets the facade crosses the insulating layer. The result is residual thermal bridges at intermediate floors, party walls and junctions, which IWI cannot wrap the way external insulation would. These bridges are limited by insulation returns, but they remain. In return, IWI is more economical, does not affect the facade and suits heritage or protected buildings.

Where do bridges remain with IWI?

Because the insulation is on the inside, it is interrupted wherever a structural element butts against the facade wall:

  • At slab edges and intermediate floors: the slab links the heated inside to the cold facade.
  • At party walls: the internal load-bearing wall crosses the insulation at every junction with the facade — the most characteristic bridge of IWI.
  • At the wall-floor junction and at the base of the wall (ground floor).
  • Around the windows, where the insulation return is more constrained than from the outside.

How to limit these residual bridges?

They are not removed, but they are reduced by workmanship measures:

  • Insulation returns: extend the insulation over a sufficient depth along party walls, reveals and floor ends, to move the cold point away from the internal corner.
  • High-performance insulation on a small thickness where space is tight, in order to keep a useful return without reducing the living space.
  • Air-tightness treatment and vapour management, since IWI is sensitive to the risk of condensation within the wall (the wall, now cold, may allow vapour to migrate).
Residual bridge after return:  Hψ = ψresidual · L  (ψ reduced but not zero, to be calculated)

The extent of the residual bridge is determined by the default values of EN ISO 14683 or by a detailed ISO 10211 calculation. The risk of condensation, on the surface as within the wall, is assessed by EN ISO 13788 (the fRsi factor and the Glaser method).

A point of vigilance: condensation within the wall

With IWI, the load-bearing wall ends up on the cold side of the insulation. The water vapour from inside can then condense in contact with the cold wall if humidity management is insufficient. This risk, specific to IWI, is controlled by a suitable vapour barrier or vapour control layer on the inside and by effective ventilation of the dwelling. This is an important difference from EWI, which leaves the wall on the warm, dry side.

When is IWI preferable?

Despite its residual bridges, IWI remains the right choice in several situations:

SituationWhy IWI
Heritage facade or protected areaThe external appearance must be preserved; EWI is prohibited or not advised
Shared boundaries, alignment with the streetNo room available on the outside
Constrained budget, room-by-room renovationLower cost, works that can be staged
Intermittently heated premisesFaster response in reaching temperature
The choice between IWI and EWI depends on the building, the heritage value, the budget and the planning constraints. Neither "removes all thermal bridges": they reduce them differently, and the result is verified by calculation or measurement. These benchmarks do not replace a project study.

Verifying the result

As with any intervention, the reduction achieved is established by standardised calculation (EN ISO 14683 / ISO 10211, integrated into the energy balance depending on local regulations) or by in-situ thermography (EN 13187), targeting the party-wall corners and the floor ends. Results from the laboratory, from simulation and from the building site are distinguished, as they carry different weight.

Limits of interpretation

  • Insulation returns reduce the bridges but do not cancel them: a residual bridge must be documented in the balance.
  • IWI slightly reduces the living space and requires careful management of water vapour.
  • The default values of EN ISO 14683 are conservative; an ISO 10211 calculation is more reliable.
  • On a building where EWI is possible and permitted, it treats party walls and floors better; the choice remains specific to each project.

This guide complements the Thermal correction of buildings dossier and the Thermal bridges cluster. The external strategy is detailed in the Treatment by EWI guide. Isoltech Green is a European distributor; the choice of a solution falls to a project study.